Permission to display a sign, either granted automatically within set limits (deemed consent) or by the council on application (express consent). Each UK nation has its own regulations, and displaying an advert without consent is a criminal offence.
Anodising
An electrochemical process that thickens the oxide layer on aluminium, giving a hard metallic finish in silver, bronze or black tones. Qualanod is the quality label for this kind of finish.
Approved Document
Government guidance on meeting the building regulations, published separately for England and for Wales. Wales keeps Part N for glazing, while Scotland uses the Technical Handbook and Northern Ireland uses Technical Booklets.
Area of special control
An area with tighter limits on signs. England, Wales and Scotland drop the top height to 3.6m, lit signs lose their deemed route in England and Scotland, and Northern Ireland's Regulations don't use the term.
Article 4 direction
A direction, usually made by the council, that withdraws permitted development rights in a defined area. We found no permitted development route for changing a shopfront in any UK nation, so ask the council whether a direction touches any related work.
Back-painted glass
Glass coated on its rear face so it reads as a solid colour from the front. It hides structure or rooms behind while matching the surface of the clear panes beside it.
BS EN 12600
The pendulum impact test and classification for flat glass, which shows how safely a pane breaks. Guidance in England and Northern Ireland uses Class 3, or Class 2 for door panes over 900mm wide, while Wales refers to BS 6206 and Scotland to BS 6262-4.
BS EN 16005
The standard for safety in use of power-operated pedestrian doorsets, such as automatic sliding doors. Its current edition is dated 2023.
BS EN 356
The standard that tests and classifies security glazing against manual attack. A class such as P6B describes what the glass resisted in the test, and it isn't a promise that the glass can't be broken.
Building control
The service that checks building work against the regulations. England and Wales work from Approved Documents and Northern Ireland from Technical Booklets, while Scotland uses building warrants.
Building warrant
Scotland's approval for building work, assessed against the Technical Handbook. Replacing a door or window with its frame needs no warrant, though the standards still apply, and altering a wall or structure should be treated as needing one.
Built-up letters
Individual three-dimensional letters fixed to a fascia or wall, in place of a flat printed panel. They are usually made from metal or acrylic and can be lit from inside or behind.
CDM principal designer
The person a commercial client appoints to lead on health and safety during design when a job has more than one contractor. CDM 2015 applies in Great Britain and CDM (NI) 2016 in Northern Ireland.
Class E
England's use class that includes shops, with retail at Class E(a), in force since 1 September 2020. Wales keeps A1, A2 and A3, Scotland has Class 1A, and Northern Ireland has A1 and A2.
Conservation area
An area protected for its special character, where extra controls apply. Lit signs lose their deemed route in all four UK nations, and demolition needs planning permission in England but conservation area consent in Wales, Scotland and Northern Ireland.
Console
The decorative bracket at each end of a traditional fascia, usually sitting above the pilaster. It closes off the fascia and gives a heritage front much of its character.
Corbel
A projecting block that supports something above it, such as a cornice. On shopfronts the word is often used loosely for a console.
Cornice
The projecting moulding along the top of a fascia. It throws rain clear of the sign and casts the shadow line that finishes the front.
Critical glazing
Glass in positions where people are most likely to strike it, broadly low panes and glass in or beside doors. The guidance is Approved Document K in England, Approved Document N in Wales, the Technical Handbook in Scotland and Booklet V in Northern Ireland.
Curtain walling
A non-loadbearing glazed facade fixed to the building's frame, usually across several floors. BS EN 13830 is its product standard.
Permission given by the advertisement regulations themselves, so a sign within the set limits needs no application. The classes and limits differ in England, Wales, Scotland and Northern Ireland.
Dilapidations
The repairs a tenant owes a landlord under a lease, usually assessed at the end of the term. Check whether your lease expects the original frontage to be put back before you change it.
Dutyholder
The employer or person with control of premises, who carries fire safety duties in Scotland and Northern Ireland. England and Wales use the term responsible person.
Entablature
The horizontal band across the top of a traditional shopfront, made up of cornice, fascia and a lower moulding. Pilasters on each side carry it, at least visually.
Advertisement consent granted by the council on application, needed when a sign falls outside the deemed consent limits. A lit sign in a conservation area is a common example.
Fanlight
A glazed panel above a door, usually set over a transom. On older fronts it may be original, so check before replacing it.
Fascia
The horizontal band above the shop window that carries the name. Its depth does more to set the proportions of a front than almost any other dimension.
Floor spring
A door closer set in a box in the floor, under the door's pivot. It keeps the mechanism out of sight, which is why frameless glass doors so often use one.
Glazing bead
The strip that holds a pane in its frame. On a security window it belongs on the inside, where it can't be removed from the street.
Halo lighting
Light from behind a solid letter, so it washes the wall and the letter reads as a dark shape with a soft glow. England, Wales and Northern Ireland name halo lighting in their lit sign classes, while Scotland's class asks for each character to be lit from within.
Hoarding
A temporary close-boarded screen around work beside a street. In England and Wales, section 172 of the Highways Act 1980 requires one before external alterations unless it's waived, and Northern Ireland deals with it under Article 72 of its Roads Order.
Laminated glass
Two or more panes bonded with a plastic interlayer, so the glass stays in place when it breaks. It's used for safety and security, and the interlayer also filters much of the ultraviolet.
Like-for-like replacement
Replacing something with the same design, materials and appearance. It usually needs no planning permission, but England and Wales have no matching exemption from building regulations, so ask building control.
Permission for works to a listed building, separate from planning permission. It's decided by the local planning authority in England, planning authorities and Welsh Ministers in Wales, the planning authority in Scotland and the council in Northern Ireland.
Low-iron glass
Glass made with less iron oxide, which removes most of the green tint of standard glass. Whites look whiter and thick edges look clear, at a higher cost.
LPS 1175
The LPCB intruder resistance standard, at Issue 8.2 from September 2024. Grades such as B3 combine a tool category and a delay in minutes.
Manifestation
Markings on glass doors and screens that make the glass visible. All four UK nations use two bands, 850 to 1000mm and 1400 to 1600mm above the floor.
Material alteration
Under the building regulations in England and Wales, work that leaves a building further from meeting certain requirements, including structure, fire safety and access.
Mullion
A vertical bar that divides panes of glass within a frame. Its face width is one of the main sightlines on a shopfront.
Panic exit device
A horizontal bar that releases a door when pushed, tested to BS EN 1125. BS EN 179 covers the lever or push-pad devices used where people know the building.
PAS 24
A specification for enhanced security in doorsets and windows, with 2022 as the current edition. It's written for dwellings and other buildings exposed to comparable risk.
Patch fitting
A metal clamp fixed to the corner of a glass door or panel, so it can pivot or be held with no frame. Top and bottom patches usually work with a floor spring.
Permitted development
Work allowed by national order without a planning application. Shops have some of these rights, but no UK nation gives one for changing a shopfront, and shutters are expressly excluded in England and Wales.
Pilaster
A flat column shape at each side of a traditional shopfront, framing the window and carrying the fascia. It often marks the line between two units.
Powder coating
A dry coloured powder sprayed onto metal and baked to a hard finish. Qualicoat is the quality label for architectural coatings on aluminium.
RAL
A European colour reference system in which each number names one exact colour. RAL 7016, for example, is a common anthracite grey on aluminium frames.
Recessed lobby
An entrance set back from the building line, with display glass returning to the door. It adds window length and gives shelter on the doorstep.
Responsible person
The person who carries fire safety duties in England and Wales under the Regulatory Reform (Fire Safety) Order 2005. That is the employer, or the person controlling the premises for a business, or otherwise the owner.
Reveal
The side face of an opening, between the front of the wall and the frame. A deeper reveal casts more shadow and makes a front look more solid.
Scaffold licence
Permission to put scaffolding on a street: a section 169 licence in England and Wales, written permission under section 58 in Scotland and Article 72 consent in Northern Ireland. Ask the council what headroom it expects underneath.
Sealed unit
Two or more panes joined at the edges with a sealed gap between them, used to cut heat loss. It's also called a double-glazed unit.
Sightline
The visible width of a frame or bar, seen face-on. Slim, consistent sightlines are what make an aluminium front look considered.
Soffit
The underside of something overhead, such as a lobby ceiling or canopy. It's often where downlights, shutter boxes and hanging rails end up.
Stallriser
The solid base below the shop window, between the pavement and the glass. It protects the glazing and sets the height of the display.
Stick system
Curtain walling built on site from separate mullions, transoms and glass. It suits ground-floor and low-rise work where access is easy.
Structural silicone
A high-strength sealant that bonds glass to its support, so no cap or bead shows on the outside.
Technical Booklets
Northern Ireland's guidance on meeting its building regulations, with Booklet V covering glazing and Booklet R covering access.
Technical Handbook
Scotland's guidance on meeting its building standards, with a separate non-domestic volume. The April 2026 edition applies to warrants from 6 April 2026.
Thermal break
A strip of low-conductivity material between the inner and outer parts of a metal frame. It slows heat loss and reduces condensation on the frame.
Threshold
The strip at the foot of a door that the floor crosses. Guidance in all four UK nations asks for level, or 15mm at most, with upstands over 5mm chamfered.
Toughened glass
Glass heated and rapidly cooled to make it much stronger than ordinary glass, breaking into small blunt pieces. It can't be cut or drilled afterwards, so every dimension has to be right first.
Transom
A horizontal bar across a frame, often between a door and the fanlight above it.
U-value
A measure of how fast heat passes through part of a building, in W/m²K, where lower means less heat lost. England's Approved Document L sets no maximum for display windows, but does set figures for doors.
Unitised
Curtain walling delivered as pre-assembled panels, which are lifted into place and locked together on site. It costs more than a stick system but needs less work at height.