The guidance from Birmingham City Council is Jewellery Quarter Conservation Area Design Guide (Section 9: Signage, Shopfronts and Lighting) (2005). It covers the Jewellery Quarter Conservation Area only, so it doesn't apply across the whole council area.
What does the Birmingham guidance ask for?
These are the requirements we picked out when we read the document, in our own words.
The council also lists a Moseley shopfront guide, which we couldn't open, and we couldn't find its 1995 Shopfronts Design Guide online, so this summary doesn't cover either.
- There is a general presumption against security shutters on listed buildings and in the conservation area.
- Security glazing, internal grilles and demountable external grilles are the accepted alternatives to shutters.
- Internally lit signs are not permitted in a conservation area, and shopfronts and fascias should be externally lit.
- Dutch, fan and fixed blinds will not be permitted, though traditional retractable blinds will be allowed where appropriate.
- New signs should follow traditional types such as painted timber boards, relief lettering or etched windows.
What does that mean for your frontage?
Treat the guide as the council's starting position. If your design departs from it, say why in the application, because a drawing that shows the reason tends to land better than a bare request.
You can read the original here: Jewellery Quarter Conservation Area Design Guide (Section 9: Signage, Shopfronts and Lighting).
Which consents are likely in Birmingham?
A true like-for-like replacement usually needs no planning permission in England, because the external appearance isn't materially affected. New materials, a different glass line or altered proportions usually do count as material, so for shopfront work at premises in the Birmingham area, an application is then likely. The council confirms which side of that line a job falls on.
A lit projecting sign at premises in the Birmingham area has firm limits under Class 4B in England: 0.75m² per surface and 1m high. It can project 1m, or two-thirds of the footway if that is less, and it can't sit over the carriageway. A larger sign needs advertisement consent, and so does a lit one in a conservation area.
Common questions
What rules apply to a fire exit door through a shopfront in the Birmingham area?
It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.
Do I need listed building consent for a shopfront in the Birmingham area?
Usually yes, if the building is listed. In England the local planning authority decides, and Historic England is notified of Grade I and II* works and specified Grade II works. Like-for-like repair may not need consent, so ask the council before work starts.
Does a shop sign in the Birmingham area need advertisement consent?
Not always. In England, an unlit sign within Class 5 of the 2007 Advertisement Regulations generally needs no application, and neither does a lit sign within Class 4B. Anything outside those classes needs consent, and Class 4B isn't available in conservation areas, so check before ordering.