The guidance from London Borough of Camden is Camden Planning Guidance: Design (Chapter 6: Shopfronts) (2021). It tells applicants what the council expects from new and altered shopfronts.
What does the Camden guidance ask for?
These are the requirements we picked out when we read the document, in our own words.
- Existing stall risers should be kept, and new ones should be at least 300mm high or reach the top of the pilaster base or door panel.
- Solid shutters are only acceptable in exceptional circumstances, and internal security measures are strongly encouraged.
- Uncoated shutters, galvanised steel, milled finishes and anodised aluminium are not acceptable finishes.
- Properties should have one main fascia sign and one ancillary projecting or hanging sign per street frontage.
- Blinds need at least 2.3m clearance above the pavement, and doors a clear width of 1000mm in new buildings and 775mm in existing ones.
What does that mean for your frontage?
Treat the guide as the council's starting position. If your design departs from it, say why in the application, because a drawing that shows the reason tends to land better than a bare request.
You can read the original here: Camden Planning Guidance: Design (Chapter 6: Shopfronts).
Which consents are likely in Camden?
A true like-for-like replacement usually needs no planning permission in England, because the external appearance isn't materially affected. New materials, a different glass line or altered proportions usually do count as material, so for shopfront work at premises in the Camden area, an application is then likely. The council confirms which side of that line a job falls on.
A lit projecting sign at premises in the Camden area has firm limits under Class 4B in England: 0.75m² per surface and 1m high. It can project 1m, or two-thirds of the footway if that is less, and it can't sit over the carriageway. A larger sign needs advertisement consent, and so does a lit one in a conservation area.
Open Camden Planning Guidance: Design (Chapter 6: Shopfronts) on the council website
Common questions
What rules apply to a fire exit door through a shopfront in the Camden area?
It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.
Do I need listed building consent for a shopfront in the Camden area?
Usually yes, if the building is listed. In England the local planning authority decides, and Historic England is notified of Grade I and II* works and specified Grade II works. Like-for-like repair may not need consent, so ask the council before work starts.
Do roller shutters need planning permission in the Camden area?
Usually yes. Installing or replacing a security grill or shutter on a shopfront is expressly outside England's shop permitted development rights, so the only way to avoid an application is work that doesn't materially affect the appearance. Ask the council before ordering.