Knowsley shopfront guidance

A plain-English summary of Shopfront and Signage Design Supplementary Planning Document.

The guidance from Knowsley Metropolitan Borough Council is Shopfront and Signage Design Supplementary Planning Document (2023). It tells applicants what the council expects from new and altered shopfronts.

Summary written by us after reading the council's document. Checked November 2026. Not legal advice.

What does the Knowsley guidance ask for?

These are the requirements we picked out when we read the document, in our own words.

  • The stallriser should generally be no more than 20% of the shopfront's overall height.
  • The fascia should be no more than 20% of the shopfront's height and generally no deeper than 400mm.
  • Solid external roller shutters are unacceptable, and internal grilles or shutters are preferred.
  • uPVC should not be used for the fascia or stallriser, and timber is expected on traditional buildings in most cases.
  • Projecting signs should stick out no more than 450mm and not exceed 500mm in any dimension.

What does that mean for your frontage?

Look at the diagrams and photographs as closely as the words. They show what the planning officers hope to see, so borrow the logic of the proportions and leave the particular style to your brand.

You can read the original here: Shopfront and Signage Design Supplementary Planning Document.

Which consents are likely in Knowsley?

Security grilles and shutters are named in England's rules: installing or replacing one on a shopfront sits outside the shop permitted development rights. The frontage itself is treated the same way, so for shopfront work at premises in the Knowsley area, building work that materially affects the appearance needs planning permission. Confirm the position with the council before anything is ordered.

Class 4B, England's class for lit signs, isn't available in conservation areas, Areas of Outstanding Natural Beauty, National Parks or the Broads, so a lit sign there normally needs advertisement consent. In an area of special control it is unavailable too, and Class 5 drops to a 3.6m top height, 0.3m letters and one-tenth of the building face up to 3.6m. Ask the council which designations cover premises in the Knowsley area.

Open Shopfront and Signage Design Supplementary Planning Document on the council website

Common questions

Do roller shutters need planning permission in the Knowsley area?

Usually yes. Installing or replacing a security grill or shutter on a shopfront is expressly outside England's shop permitted development rights, so the only way to avoid an application is work that doesn't materially affect the appearance. Ask the council before ordering.

Does a new shopfront in the Knowsley area need Building Regulations approval?

Assume yes until building control says otherwise. England has no like-for-like exemption, though registered installers can self-certify replacement windows and doors in non-dwellings. That route doesn't cover structural glass, curtain walling or revolving doors.

What rules apply to a fire exit door through a shopfront in the Knowsley area?

It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.