The guidance from North Lanarkshire Council is Shopfronts & Security (2011). It tells applicants what the council expects from new and altered shopfronts.
What does the North Lanarkshire guidance ask for?
These are the requirements we picked out when we read the document, in our own words.
- Original stallrisers should be retained or reinstated, and new ones should be 450mm to 700mm high.
- Fascias should be horizontally proportioned and roughly 300mm to 450mm high.
- Demountable grilles are preferred, and externally stored roller shutters carry a high risk of refusal.
- Standard illuminated box signs should be avoided in favour of discreet concealed lighting such as LED spotlights.
- Adverts should cover no more than 10% of the glazed frontage, and an 800mm minimum door width is listed as a measure to consider where feasible.
What does that mean for your frontage?
Check the date on the guide and ask the planning department whether it is still the version in use. Older documents can stay in force for years, and a quick question early on costs far less than an amended application.
You can read the original here: Shopfronts & Security.
Which consents are likely in North Lanarkshire?
Scottish guidance says like-for-like windows need no permission, and a true like-for-like frontage replacement usually follows the same logic. Class 7A covers altering or replacing an existing window, but it doesn't mention shopfronts, so ask before relying on it for a display window. For shopfront work at premises in the North Lanarkshire area, a material effect on the external appearance means planning permission, and the council confirms the position.
The 0.25m projection limit in Class VI means most lit projecting signs in Scotland fall outside it. One at premises in the North Lanarkshire area will usually need advertisement consent, so allow for an application in the programme.
Open Shopfronts & Security on the council website
Common questions
Do I need planning permission to alter a shopfront in the North Lanarkshire area?
Usually yes, if the work materially affects the external appearance. Class 9A, Scotland's shop permitted development right, doesn't cover work that alters or extends beyond the existing front. A true like-for-like replacement usually needs no permission, and the council confirms the position.
Which way must a fire exit door open on a shop in the North Lanarkshire area?
In the direction of escape. Regulation 13(2) of the Fire Safety (Scotland) Regulations 2006 also rules out sliding and revolving doors on a dedicated fire exit and says fire exit doors can't be locked against immediate use. Duties sit with dutyholders under Part 3 of the Fire (Scotland) Act 2005, meaning the employer and any person with control of the premises.
Does the Equality Act cover a shop entrance in the North Lanarkshire area?
Yes. The Equality Act 2010 applies in Scotland as part of Great Britain, and its anticipatory duty expects reasonable steps to remove, alter or avoid physical features that disadvantage disabled people generally. BS 8300-2:2018 is the current British Standard for accessible buildings.