The guidance from South Kesteven District Council is South Kesteven Shopfront Design Guide (2024). It tells applicants what the council expects from new and altered shopfronts.
What does the South Kesteven guidance ask for?
These are the requirements we picked out when we read the document, in our own words.
- Retractable shutters should sit inside the building hidden behind the fascia, and external roller shutters are not acceptable on listed buildings.
- Fascias that are boxed in or project excessively are unsuitable, and signs should not be built out on an extra box or board.
- External illumination is the only acceptable option for traditional shopfronts, using static single-colour LED where lighting is accepted.
- Timber is the most appropriate material for new traditional frontages, with hardwoods preferred and modern pine considered unsuitable.
- In Stamford, prefabricated fascia panels are unlikely to be approved and illuminated signs are unlikely to be suitable.
What does that mean for your frontage?
Use the guide as a checklist at the premises. Walk the frontage with it in your hand, mark where the building already follows the advice, and note any point where you want to do something different.
You can read the original here: South Kesteven Shopfront Design Guide.
Which consents are likely in South Kesteven?
England has no permitted development route for changing a shopfront. Part 7 Class A of the General Permitted Development Order 2015 excludes creating, altering or replacing one, and it allows no alterations at all on article 2(3) land. That leaves two outcomes for shopfront work at premises in the South Kesteven area: a planning application, or work that doesn't materially affect the external appearance.
Lighting moves a sign out of Class 5 in England, because that class allows illumination only for medical-type notices. Class 4B then applies at premises in the South Kesteven area: halo or character-only lighting, static, with the lowest part at least 2.5m up. Brightness is capped at 600 cd/m² on signs up to 10m² and 300 cd/m² above that, and anything outside these limits needs advertisement consent.
Open South Kesteven Shopfront Design Guide on the council website
Common questions
Does a new shopfront in the South Kesteven area need Building Regulations approval?
Assume yes until building control says otherwise. England has no like-for-like exemption, though registered installers can self-certify replacement windows and doors in non-dwellings. That route doesn't cover structural glass, curtain walling or revolving doors.
Do roller shutters need planning permission in the South Kesteven area?
Usually yes. Installing or replacing a security grill or shutter on a shopfront is expressly outside England's shop permitted development rights, so the only way to avoid an application is work that doesn't materially affect the appearance. Ask the council before ordering.
What rules apply to a fire exit door through a shopfront in the South Kesteven area?
It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.