The guidance from London Borough of Tower Hamlets is Shopfronts and Roller Shutter Grilles, which carries no publication date. It tells applicants what the council expects from new and altered shopfronts.
What does the Tower Hamlets guidance ask for?
These are the requirements we picked out when we read the document, in our own words.
- Stallrisers are always required on traditional shopfronts.
- Fascias should normally be no more than 500mm deep and no higher than ground floor level.
- External roller shutter boxes will not be permitted, and shutters should wherever possible be an integral feature of the shopfront.
- Open mesh roller grilles or powder-coated perforated steel are encouraged over solid grilles.
- Modern aluminium shopfronts will not normally be permitted in conservation areas or on listed buildings.
What does that mean for your frontage?
Look at the diagrams and photographs as closely as the words. They show what the planning officers hope to see, so borrow the logic of the proportions and leave the particular style to your brand.
You can read the original here: Shopfronts and Roller Shutter Grilles.
Which consents are likely in Tower Hamlets?
England has no permitted development route for changing a shopfront. Part 7 Class A of the General Permitted Development Order 2015 excludes creating, altering or replacing one, and it allows no alterations at all on article 2(3) land. That leaves two outcomes for shopfront work at premises in the Tower Hamlets area: a planning application, or work that doesn't materially affect the external appearance.
Lighting moves a sign out of Class 5 in England, because that class allows illumination only for medical-type notices. Class 4B then applies at premises in the Tower Hamlets area: halo or character-only lighting, static, with the lowest part at least 2.5m up. Brightness is capped at 600 cd/m² on signs up to 10m² and 300 cd/m² above that, and anything outside these limits needs advertisement consent.
Open Shopfronts and Roller Shutter Grilles on the council website
Common questions
Do I need listed building consent for a shopfront in the Tower Hamlets area?
Usually yes, if the building is listed. In England the local planning authority decides, and Historic England is notified of Grade I and II* works and specified Grade II works. Like-for-like repair may not need consent, so ask the council before work starts.
What rules apply to a fire exit door through a shopfront in the Tower Hamlets area?
It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.
Does a new shopfront in the Tower Hamlets area need Building Regulations approval?
Assume yes until building control says otherwise. England has no like-for-like exemption, though registered installers can self-certify replacement windows and doors in non-dwellings. That route doesn't cover structural glass, curtain walling or revolving doors.