Curtain walling in Islington

Measured at your Islington premises, never guessed from a photograph.

Curtain walling gives Islington premises a glazed elevation that runs past the floor edges, where a standard shopfront frame would run out of span. We measure the structure first, then set the grid out to suit the building.

Measuring the opening is the easy part of a survey in Islington. We also look at the beam above, the pavement fall and any meters or drains nearby.

Aluminium curtain walling with slim mullions across a two-storey commercial facade at dusk

How would we approach curtain walling for your Islington premises?

Where your frontage in Islington faces open ground, wind load can push mullions a size deeper than a sheltered terrace would need. We check exposure for your elevation, so the sections are no heavier than they have to be.

Should the floors above stay occupied, the work can be phased bay by bay, with temporary weathering at the end of each shift. Tenants keep their rooms dry and the old elevation comes out in an order that suits the building.

Where the building has good brick or stone around the opening, set the frame back in the reveal so the masonry can be seen. On Islington premises with a flat elevation, that deep reveal throws a shadow line that adds real depth in low sun.

What consents could affect curtain walling in Islington?

For curtain walling at premises in the Islington area, the deciding question in England is whether the building work materially affects the external appearance. If it does, planning permission is needed, while a true like-for-like replacement usually needs none. The council confirms the position for each site.

Islington applications for planning permission or advertisement consent are normally handled by London Borough of Islington. Our survey includes a check of the position for your address.

What should you budget for curtain walling in Islington?

The guide for curtain walling is £550 to £1,250 plus VAT per m². Expect the lower end for simple work with clear access, and the upper end where detail, finish or awkward conditions add hours.

Islington at a glance
TownIslington
AreaGreater London
Postcode districtsEC1, EC1R, EC1V, N1
Planning authorityLondon Borough of Islington
Building approvalBuilding Regulations (Approved Documents)
Distance from Great BarrAbout 104 miles
SurveyFree for new work

Questions about curtain walling in Islington

What should I send before a survey of my Islington premises?

The address, a few photographs and any existing drawings are enough to start. Tell us how the building is used and which floors stay occupied, because that shapes the access plan.

Can you match the frames already on my Islington building?

Usually, yes. Colour can be matched to a RAL reference or a sample, and cap profiles can be chosen to sit close to what is there. An exact match on an old system may not be possible, in which case we would suggest a deliberate change at a natural break.

Can part of an elevation in Islington be done first?

Yes, provided the break falls at a sensible mullion. Phasing can spread cost and disruption, although two visits usually cost more than one. We would draw the whole elevation first so the second phase matches.

Does a shop sign in the Islington area need advertisement consent?

Not always. In England, an unlit sign within Class 5 of the 2007 Advertisement Regulations generally needs no application, and neither does a lit sign within Class 4B. Anything outside those classes needs consent, and Class 4B isn't available in conservation areas, so check before ordering.

What rules apply to a fire exit door through a shopfront in the Islington area?

It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.

Planning curtain walling in Islington?

Send the address and a photo, and we'll come and measure it.