0800 088 6248 Get a guide price
  1. Home
  2. Services
  3. Curtain walling
  4. St James's

Curtain walling in St James's

Survey, drawings and a written price for curtain walling in St James's.

From a single-bay stair tower to a full frontage, we design and fit curtain walling for premises in St James's and the surrounding parts of Greater London. One contract covers the frame, the glass and the junction with the shopfront below.

Nothing gets ordered off the back of a survey in St James's, because its job is to give us the numbers to draw and price from.

Aluminium curtain walling with slim mullions across a two-storey commercial facade at dusk

What makes curtain walling work well on St James's premises?

Should the floors above stay occupied, the work can be phased bay by bay, with temporary weathering at the end of each shift. Tenants keep their rooms dry and the old elevation comes out in an order that suits the building.

Where the building already has curtain walling, we test whether the brackets and framing can be reused. Keeping a sound frame and changing the glass and caps can give most of the result with far less disruption.

A corner unit has two fronts to think about, and the return elevation often does as much selling as the main one. If that is your layout in St James's, carry the fascia and glass line round the corner and treat both faces as one composition.

Could curtain walling in St James's need planning permission?

England has no permitted development route for changing a shopfront. Part 7 Class A of the General Permitted Development Order 2015 excludes creating, altering or replacing one, and it allows no alterations at all on article 2(3) land. That leaves two outcomes for curtain walling at premises in the St James's area: a planning application, or work that doesn't materially affect the external appearance.

At survey we check how things stand for your building, although applications for planning permission or advertisement consent here normally go to Westminster City Council.

How much should you set aside for curtain walling in St James's?

Until the survey is done, plan on £550 to £1,250 plus VAT per m². Unusual sizes, fine detail and phased working push the figure up, while a simple brief and clear access keep it toward the lower end.

St James's at a glance
TownSt James's
AreaGreater London
Postcode districtsSW1Y, W1F, W1J, W1S
Planning authorityWestminster City Council
Building approvalBuilding Regulations (Approved Documents)
Distance from Great BarrAbout 104 miles
SurveyFree for new work

Does Westminster City Council publish shopfront guidance?

Yes, Shopfronts, Blinds and Signs - A Guide to their Design (1993). It tells applicants what the council expects from new and altered shopfronts. A few of the things it asks for:

  • Roller shutters will not normally be given consent, and internally fitted brick-bond grilles are the preferred solution.
  • Large internally lit box signs are generally inappropriate, while externally lit fascias and back-lit or halo-lit letters are accepted.
  • Projecting signs need at least 2.6m clearance above the pavement and should sit at fascia level, centred on a pilaster.

Read our summary of the Westminster guidance

Questions about curtain walling in St James's

Is curtain walling right for a single-storey unit in St James's?

Usually not. A well-designed aluminium shopfront will span most single-storey openings with slimmer sections and lower cost. Curtain walling starts to make sense once the glass runs past a floor edge or the opening is unusually tall.

Can part of an elevation in St James's be done first?

Yes, provided the break falls at a sensible mullion. Phasing can spread cost and disruption, although two visits usually cost more than one. We would draw the whole elevation first so the second phase matches.

Can you replace failing curtain walling on premises in St James's?

Yes. We survey the frame, brackets and seals first, because some elevations only need new glass and gaskets. If the frame itself has failed, we draw a replacement that can be phased around the building's use.

Does a new shopfront in the St James's area need Building Regulations approval?

Assume yes until building control says otherwise. England has no like-for-like exemption, though registered installers can self-certify replacement windows and doors in non-dwellings. That route doesn't cover structural glass, curtain walling or revolving doors.

What rules apply to a fire exit door through a shopfront in the St James's area?

It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.

Planning curtain walling in St James's?

Send the address and a photo, and we'll come and measure it.

Call usGet a guide price