A slim framed slider can sit inside an existing Maida Hill frontage with little change to the outside. The drive hides behind the fascia, and the leaves line up with the screens either side.
We measure your Maida Hill opening in person, at a time agreed with you first, so the visit fits around your trading.

What makes automatic sliding doors work well on Maida Hill premises?
In a parade in Maida Hill with a narrow pavement, the sensor set-up is the first job. We'd angle the radar so people walking past don't trigger the door, and keep the leaves in line with the neighbouring frontage.
For a pharmacy or retail chain with a branch in Maida Hill, we'd keep the door type, finish and settings the same as the estate standard. Opening width and head detail then adapt to this particular front.
If your premises were once two shops, decide early whether the front should read as one or as two. One continuous fascia with a repeated bay width usually settles the elevation better than two mismatched halves, which is worth testing on any Maida Hill unit of that kind.
Could automatic sliding doors in Maida Hill need planning permission?
England has no permitted development route for changing a shopfront. Part 7 Class A of the General Permitted Development Order 2015 excludes creating, altering or replacing one, and it allows no alterations at all on article 2(3) land. That leaves two outcomes for automatic sliding doors at premises in the Maida Hill area: a planning application, or work that doesn't materially affect the external appearance.
Planning and advert applications for Maida Hill premises normally go to Westminster City Council. We check the position for your address at survey.
How much should you set aside for automatic sliding doors in Maida Hill?
Allow £3,895 to £11,995 plus VAT per entrance. Size and specification set most of that figure for automatic sliding doors, and the rest depends on what the survey finds on site.
| Town | Maida Hill |
|---|---|
| Area | Greater London |
| Postcode districts | NW6, NW8, W2, W9 |
| Planning authority | Westminster City Council |
| Building approval | Building Regulations (Approved Documents) |
| Distance from Great Barr | About 102 miles |
| Survey | Free for new work |
Does Westminster City Council publish shopfront guidance?
Yes, Shopfronts, Blinds and Signs - A Guide to their Design (1993). It tells applicants what the council expects from new and altered shopfronts. A few of the things it asks for:
- Roller shutters will not normally be given consent, and internally fitted brick-bond grilles are the preferred solution.
- Large internally lit box signs are generally inappropriate, while externally lit fascias and back-lit or halo-lit letters are accepted.
- Projecting signs need at least 2.6m clearance above the pavement and should sit at fascia level, centred on a pilaster.
Questions about automatic sliding doors in Maida Hill
Can an automatic door work with my Maida Hill shop's alarm and locks?
Yes. The door can lock at closing, and it can link to your alarm or access control where the systems allow, with a manual key position as a fallback.
Will the door keep opening for passers-by in Maida Hill?
Not if it is set up properly. We narrow the sensor field on site and test it against real footfall, so only people heading for the door trigger it.
Who installs automatic doors in Maida Hill?
Vetted door teams working under S&K Glazing handle the fit and set-up, travelling from Great Barr. Your agreement is with S&K Glazing Limited, and one person stays your point of call.
Do I need planning permission to change a shopfront in the Maida Hill area?
Usually yes, if the work materially affects the building's external appearance. England's shop permitted development rights exclude creating, altering or replacing a shopfront, so there is no shortcut. A true like-for-like replacement usually needs no application, and the council confirms the position.
Does a shop sign in the Maida Hill area need advertisement consent?
Not always. In England, an unlit sign within Class 5 of the 2007 Advertisement Regulations generally needs no application, and neither does a lit sign within Class 4B. Anything outside those classes needs consent, and Class 4B isn't available in conservation areas, so check before ordering.