From a single-bay stair tower to a full frontage, we design and fit curtain walling for premises in Barnes and the surrounding parts of Greater London. One contract covers the frame, the glass and the junction with the shopfront below.
Your survey is where the price gets real, because widths, heights, levels and access are all taken on site in Barnes.

How do you design around the building when planning curtain walling in Barnes?
Where the elevation faces south or west, solar control glass can do more for comfort than any blind. If it looks north, we would usually keep the glass clear and neutral, so the building does not turn dull on a grey day.
Where your frontage in Barnes faces open ground, wind load can push mullions a size deeper than a sheltered terrace would need. We check exposure for your elevation, so the sections are no heavier than they have to be.
If your premises were once two shops, decide early whether the front should read as one or as two. One continuous fascia with a repeated bay width usually settles the elevation better than two mismatched halves, which is worth testing on any Barnes unit of that kind.
What might curtain walling cost in Barnes?
Our guide band is £550 to £1,250 plus VAT per m². Scope is the biggest lever, so a tighter brief for curtain walling brings the figure down faster than any change of detail.
What permissions should you check for curtain walling in Barnes?
England has no permitted development route for changing a shopfront. Part 7 Class A of the General Permitted Development Order 2015 excludes creating, altering or replacing one, and it allows no alterations at all on article 2(3) land. That leaves two outcomes for curtain walling at premises in the Barnes area: a planning application, or work that doesn't materially affect the external appearance.
We confirm the position at survey, because a boundary or a special designation can change who handles the file, but applications from Barnes premises normally go to London Borough of Richmond upon Thames.
| Town | Barnes |
|---|---|
| Area | Greater London |
| Postcode districts | SW13, SW14, SW15, W4 |
| Planning authority | London Borough of Richmond upon Thames |
| Building approval | Building Regulations (Approved Documents) |
| Distance from Great Barr | About 103 miles |
| Survey | Free for new work |
Does London Borough of Richmond upon Thames publish shopfront guidance?
Yes, Shopfronts: Supplementary Planning Document (2010). It tells applicants what the council expects from new and altered shopfronts. A few of the things it asks for:
- The fascia should be no deeper than the cornice and architrave combined, and no more than one-fifth of total shopfront height.
- External roller shutters are unlikely to be permitted, and internal grilles are the only acceptable security form in conservation areas and on listed buildings.
- Internally lit box fascia signs will usually be resisted, with externally lit fascias generally preferred.
Questions about curtain walling in Barnes
Can part of an elevation in Barnes be done first?
Yes, provided the break falls at a sensible mullion. Phasing can spread cost and disruption, although two visits usually cost more than one. We would draw the whole elevation first so the second phase matches.
How disruptive is curtain walling for neighbours in Barnes?
Most disruption comes from access equipment and deliveries, not from noisy work. We plan unloading and any scaffold around nearby premises, and we keep the working area screened and tidy at the end of each shift.
What should I send before a survey of my Barnes premises?
The address, a few photographs and any existing drawings are enough to start. Tell us how the building is used and which floors stay occupied, because that shapes the access plan.
Do I need listed building consent for a shopfront in the Barnes area?
Usually yes, if the building is listed. In England the local planning authority decides, and Historic England is notified of Grade I and II* works and specified Grade II works. Like-for-like repair may not need consent, so ask the council before work starts.
What rules apply to a fire exit door through a shopfront in the Barnes area?
It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.