0800 088 6248 Get a guide price
  1. Home
  2. Services
  3. Curtain walling
  4. Wishaw

Curtain walling in Wishaw

Survey, drawings and a written price for curtain walling in Wishaw.

From a single-bay stair tower to a full frontage, we design and fit curtain walling for premises in Wishaw and the surrounding parts of Lanarkshire. One contract covers the frame, the glass and the junction with the shopfront below.

Please have keys to any meter cupboards and shutter housings to hand when we survey in Wishaw, because what sits behind them can change the drawing.

Aluminium curtain walling with slim mullions across a two-storey commercial facade at dusk

Where should you begin with curtain walling in Wishaw?

If your Wishaw premises have a concrete frame, we open up a sample of slab edges at survey and plan brackets around what is really there. Steel frames and older masonry piers each need a different fixing, so nothing is priced from assumptions.

Where your frontage in Wishaw faces open ground, wind load can push mullions a size deeper than a sheltered terrace would need. We check exposure for your elevation, so the sections are no heavier than they have to be.

If there are storeys above the shop, the frontage should feel like the base of the building and not a sign stuck on it. Lining up mullions with the windows overhead is a small move that settles the whole elevation at Wishaw premises.

What sign-off might you need for curtain walling in Wishaw?

Class 9A, Scotland's shop permitted development right, gives no route for a shopfront change. It covers Class 1A premises, but not work that alters or extends beyond the existing front, and it doesn't apply in conservation areas, National Parks or World Heritage Sites. For curtain walling at premises in the Wishaw area, that generally means a planning application unless the external appearance isn't materially affected.

For Wishaw, the usual route for planning and advert applications is through North Lanarkshire Council, and we confirm that when we visit.

What price should you expect for curtain walling in Wishaw?

A sensible starting budget is £550 to £1,250 plus VAT per m². What shifts the figure is whatever can't be seen yet, such as the condition behind the old frontage or the services running through it.

Wishaw at a glance
TownWishaw
AreaLanarkshire
Postcode districtsML2
Planning authorityNorth Lanarkshire Council
Building approvalBuilding warrant (Technical Handbook)
Distance from Great BarrAbout 237 miles
SurveyFree for new work

Does North Lanarkshire Council publish shopfront guidance?

Yes, Shopfronts & Security (2011). It tells applicants what the council expects from new and altered shopfronts. A few of the things it asks for:

  • Original stallrisers should be retained or reinstated, and new ones should be 450mm to 700mm high.
  • Fascias should be horizontally proportioned and roughly 300mm to 450mm high.
  • Demountable grilles are preferred, and externally stored roller shutters carry a high risk of refusal.

Read our summary of the North Lanarkshire guidance

Questions about curtain walling in Wishaw

Is curtain walling right for a single-storey unit in Wishaw?

Usually not. A well-designed aluminium shopfront will span most single-storey openings with slimmer sections and lower cost. Curtain walling starts to make sense once the glass runs past a floor edge or the opening is unusually tall.

How disruptive is curtain walling for neighbours in Wishaw?

Most disruption comes from access equipment and deliveries, not from noisy work. We plan unloading and any scaffold around nearby premises, and we keep the working area screened and tidy at the end of each shift.

Can part of an elevation in Wishaw be done first?

Yes, provided the break falls at a sensible mullion. Phasing can spread cost and disruption, although two visits usually cost more than one. We would draw the whole elevation first so the second phase matches.

Which way must a fire exit door open on a shop in the Wishaw area?

In the direction of escape. Regulation 13(2) of the Fire Safety (Scotland) Regulations 2006 also rules out sliding and revolving doors on a dedicated fire exit and says fire exit doors can't be locked against immediate use. Duties sit with dutyholders under Part 3 of the Fire (Scotland) Act 2005, meaning the employer and any person with control of the premises.

Do I need listed building consent for a shopfront in the Wishaw area?

Almost certainly, if the building is listed and windows or doors are changing, according to Historic Environment Scotland. The planning authority decides, and Historic Environment Scotland is consulted on some applications. Scottish Ministers are notified if it objects.

Planning curtain walling in Wishaw?

Send the address and a photo, and we'll come and measure it.

Call usGet a guide price