Landlords, shopfitters and architects working in Herne Bay can use the service as a full package or for one difficult detail. Either way the drawings start from a measured survey.
It helps if you can be there when we visit Herne Bay, since five minutes walking the frontage together answers more than a long email.

How do you design around the building when planning shopfront design in Herne Bay?
If your brand is new to Herne Bay, we look at how far the guidelines need adapting to this building. A logo may need a different size or layout on a shallow fascia, and that is worth settling early.
For a corner unit in Herne Bay, we design both elevations as one. The return, the door position and the sign all depend on which street brings your customers.
Where the footway outside your Herne Bay premises is narrow, a recessed entrance earns its keep. It gives people a dry place to pause out of the walkway, and it adds a longer run of display glass either side of the door.
What permissions should you check for shopfront design in Herne Bay?
England has no permitted development route for changing a shopfront. Part 7 Class A of the General Permitted Development Order 2015 excludes creating, altering or replacing one, and it allows no alterations at all on article 2(3) land. That leaves two outcomes for shopfront work at premises in the Herne Bay area: a planning application, or work that doesn't materially affect the external appearance.
Expect planning and advert applications here to go to Canterbury City Council in the normal way. We check what that means for your building when we survey it in Herne Bay.
What might shopfront design cost in Herne Bay?
We would budget £495 to £2,495 plus VAT per frontage. Scope sets most of the figure, so a clear brief at the start does more for the budget than any later change of detail.
| Town | Herne Bay |
|---|---|
| Area | Kent |
| Postcode districts | CT6 |
| Planning authority | Canterbury City Council |
| Building approval | Building Regulations (Approved Documents) |
| Distance from Great Barr | About 153 miles |
| Survey | Free for new work |
Does Canterbury City Council publish shopfront guidance?
Yes, Shopfront design Supplementary Planning Document (2020). It tells applicants what the council expects from new and altered shopfronts. A few of the things it asks for:
- Fascia depth must not exceed the depth of the console, or one-fifth of the distance from console to pavement.
- External solid roller shutters are not normally supported in conservation areas or main shopping streets and are unacceptable on listed buildings.
- Internally lit box signs, illuminated letters and window neon are unsuitable in conservation areas, with external lighting only for premises open at night.
Questions about shopfront design in Herne Bay
Can you show the design to my landlord in Kent?
Yes. The drawings and visuals are prepared so a landlord or agent can review them easily. We can answer their questions directly if that helps.
How many options will I see for my Herne Bay premises?
Usually two or three directions at concept stage, then one developed design. If you already know what you want, we can go straight to the developed drawings.
Do I need a design service for a simple Herne Bay shopfront?
Not always. Every job gets a measured survey and scale drawings anyway. The design service adds options, visuals and a full specification, which pay off when the look matters most.
Does the Equality Act apply to a shop entrance in the Herne Bay area?
Yes. The Equality Act 2010 applies in England, as across Great Britain, and it requires reasonable steps to remove, alter or avoid physical features that disadvantage disabled people. The duty is anticipatory, so it looks at disabled people generally, and a new Services Code replaced the 2011 Code on 5 August 2026.
What rules apply to a fire exit door through a shopfront in the Herne Bay area?
It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.