Curtain walling gives Bow premises a glazed elevation that runs past the floor edges, where a standard shopfront frame would run out of span. We measure the structure first, then set the grid out to suit the building.
Bring whatever you have to the survey in Bow: brand guidelines, lease plans, old drawings or a photo of a frontage you admire.

How would we approach curtain walling for your Bow premises?
Where the elevation faces south or west, solar control glass can do more for comfort than any blind. If it looks north, we would usually keep the glass clear and neutral, so the building does not turn dull on a grey day.
Should the floors above stay occupied, the work can be phased bay by bay, with temporary weathering at the end of each shift. Tenants keep their rooms dry and the old elevation comes out in an order that suits the building.
Where units share one long run of fascia, breaking the height makes you stand out for the wrong reason. If that describes your Bow parade, keep the line and win attention with lettering, lighting and what's in the window.
What consents could affect curtain walling in Bow?
For curtain walling at premises in the Bow area, the deciding question in England is whether the building work materially affects the external appearance. If it does, planning permission is needed, while a true like-for-like replacement usually needs none. The council confirms the position for each site.
Bow applications for planning permission or advertisement consent are normally handled by London Borough of Tower Hamlets. Our survey includes a check of the position for your address.
What should you budget for curtain walling in Bow?
Guide price: £550 to £1,250 plus VAT per m². Materials, finish and the amount of drawing and coordination involved all move it, and your itemised quotation shows where the money goes on curtain walling.
| Town | Bow |
|---|---|
| Area | Greater London |
| Postcode districts | E14, E15, E3, E9 |
| Planning authority | London Borough of Tower Hamlets |
| Building approval | Building Regulations (Approved Documents) |
| Distance from Great Barr | About 107 miles |
| Survey | Free for new work |
Does London Borough of Tower Hamlets publish shopfront guidance?
Yes, Shopfronts and Roller Shutter Grilles. It tells applicants what the council expects from new and altered shopfronts. A few of the things it asks for:
- Stallrisers are always required on traditional shopfronts.
- Fascias should normally be no more than 500mm deep and no higher than ground floor level.
- External roller shutter boxes will not be permitted, and shutters should wherever possible be an integral feature of the shopfront.
Questions about curtain walling in Bow
What should I send before a survey of my Bow premises?
The address, a few photographs and any existing drawings are enough to start. Tell us how the building is used and which floors stay occupied, because that shapes the access plan.
Can you replace failing curtain walling on premises in Bow?
Yes. We survey the frame, brackets and seals first, because some elevations only need new glass and gaskets. If the frame itself has failed, we draw a replacement that can be phased around the building's use.
Can part of an elevation in Bow be done first?
Yes, provided the break falls at a sensible mullion. Phasing can spread cost and disruption, although two visits usually cost more than one. We would draw the whole elevation first so the second phase matches.
Does a shop sign in the Bow area need advertisement consent?
Not always. In England, an unlit sign within Class 5 of the 2007 Advertisement Regulations generally needs no application, and neither does a lit sign within Class 4B. Anything outside those classes needs consent, and Class 4B isn't available in conservation areas, so check before ordering.
Does a new shopfront in the Bow area need Building Regulations approval?
Assume yes until building control says otherwise. England has no like-for-like exemption, though registered installers can self-certify replacement windows and doors in non-dwellings. That route doesn't cover structural glass, curtain walling or revolving doors.