0800 088 6248 Get a guide price
  1. Home
  2. Services
  3. Curtain walling
  4. Lee

Curtain walling in Lee

Measured at your Lee premises, never guessed from a photograph.

Curtain walling gives Lee premises a glazed elevation that runs past the floor edges, where a standard shopfront frame would run out of span. We measure the structure first, then set the grid out to suit the building.

Expect us to measure the opening, photograph the existing front and check how materials will reach it on the day, at a time you have agreed.

Aluminium curtain walling with slim mullions across a two-storey commercial facade at dusk

How would we approach curtain walling for your Lee premises?

Where the building already has curtain walling, we test whether the brackets and framing can be reused. Keeping a sound frame and changing the glass and caps can give most of the result with far less disruption.

If the frontage joins a neighbouring building in Lee, we draw that junction in full at design stage. The last mullion, the flashing and the movement joint are details people notice from the pavement.

If the pavement falls across your frontage, let the stallriser take up the slope and keep the glass line dead level. The eye reads the long horizontal, so Lee premises on a slope look settled once that line is true.

What consents could affect curtain walling in Lee?

For curtain walling at premises in the Lee area, the deciding question in England is whether the building work materially affects the external appearance. If it does, planning permission is needed, while a true like-for-like replacement usually needs none. The council confirms the position for each site.

Planning and advert applications for Lee premises normally go to London Borough of Lewisham. We check the position for your address at survey.

What should you budget for curtain walling in Lee?

We would budget £550 to £1,250 plus VAT per m². Scope sets most of the figure, so a clear brief at the start does more for the budget than any later change of detail.

Lee at a glance
TownLee
AreaGreater London
Postcode districtsSE12, SE13, SE3, SE6
Planning authorityLondon Borough of Lewisham
Building approvalBuilding Regulations (Approved Documents)
Distance from Great BarrAbout 111 miles
SurveyFree for new work

Does Lewisham Council publish shopfront guidance?

Yes, Shopfront design guide, a supplementary planning document (2006). It tells applicants what the council expects from new and altered shopfronts. A few of the things it asks for:

  • Fascias should generally be about 600mm high, never more than 900mm, and should not run unbroken across separate buildings.
  • Solid external roller shutters are not acceptable, and open mesh or grille shutters should be powder coated with the box hidden behind the fascia.
  • Internally lit fascia boxes are not allowed in conservation areas, with external lighting preferred.

Read our summary of the Lewisham guidance

Questions about curtain walling in Lee

What should I send before a survey of my Lee premises?

The address, a few photographs and any existing drawings are enough to start. Tell us how the building is used and which floors stay occupied, because that shapes the access plan.

Who do I deal with during a curtain walling job in Lee?

You have one named contact from survey to handover. The contract is with S&K Glazing Limited, and vetted teams working under S&K Glazing carry out the work.

Can you replace failing curtain walling on premises in Lee?

Yes. We survey the frame, brackets and seals first, because some elevations only need new glass and gaskets. If the frame itself has failed, we draw a replacement that can be phased around the building's use.

Do I need listed building consent for a shopfront in the Lee area?

Usually yes, if the building is listed. In England the local planning authority decides, and Historic England is notified of Grade I and II* works and specified Grade II works. Like-for-like repair may not need consent, so ask the council before work starts.

What rules apply to a fire exit door through a shopfront in the Lee area?

It must open in the direction of escape and can't be locked against immediate use, and a dedicated fire exit can't be a sliding or revolving door. In England that comes from article 14(2) of the Regulatory Reform (Fire Safety) Order 2005, and the duty sits with the responsible person, normally the employer or whoever controls the premises for a business, otherwise the owner. An outward door can clash with section 153 of the Highways Act 1980 where it opens onto the footway, so raise it early.

Planning curtain walling in Lee?

Send the address and a photo, and we'll come and measure it.

Call usGet a guide price